Communication Protocol |
Data Channel Characteristics | 1200, 2400, 4800, 9600, 14,400 and 19,200 baud (softwareselectable) |
Functional Specifications |
Power | 5VDC from console, 0.5 watts maximum consumption |
Operating Temperature | +14° to 140° F ( - 10° to 60° C) |
Data Logger Functions |
Control Functions | Set archive interval, set/clear calibration numbers, set Longitude/ Latitude, set Year - to - Date rain total, set/clear alarm thresholds, clear total values, set time/date. |
Download | Data may be transferred automatically from the data logger to your computer up to once an hour using the Auto Download command. Data can be transferred more frequently, from once a minute to once every two hours, to support Internet uploading and other data sharing features. Only new archive data is transferred during the download. |
Data Logger Archived Data |
Archive Record Data | Time/Date of Record, Inside Temperature (last or average), Outside Temperature (last or average), Maximum Air Temperature, Minimum Air Temperature, Wind Direction (dominant), Wind Speed (average), Maximum Wind Speed, Wind Direction at Maximum Wind Speed, Rainfall (total), Rain Rate, Inside Humidity (last), Outside Humidity (last), Barometric Pressure (last), Solar Radiation, Hi Solar Radiation, UV, Hi UV, Evapotranspiration, Leaf Temperature (2), Leaf Wetness (2), Extra Humidity (2), Extra Temperature (3), Soil Temperature (4), Soil Moisture (4), Wind Samples, Wind Transmitter ID, Length of Archive Interval, ISS Reception |
Archive Interval | User - selectable from the following intervals (in minutes): 1, 5, 10, 15, 30, 60, or 120 |
Archive Storage Capacity (the amount of time before the archive is completely filled) |
1 Minute Archive Interval | 42 hours |
5 Minute Archive Interval | 8 days |
10 Minute Archive Interval | 17 days |
15 Minute Archive Interval | 26 days |
30 Minute Archive Interval | 53 days |
60 Minute Archive Interval | 106 days |
120 Minute Archive Interval | 213 days |